RCM-SCLT Fuori produzione

Screen and Lighting Control Module
Caratteristiche principali
  • For use with the MLC 206, MLC 226 IP, and MLC 104 IP Plus MediaLink® Controllers and System 5 IP system switcher
  • Provides control to position a projection screen and adjust light settings
  • Available in black, white, or RAL9010 white
The Extron RCM-SCLT
Descrizione prodotto Codice articolo
  Gray 70-184-01 Fuori produzione
  Black 70-184-02 Fuori produzione
  White 70-184-03 Fuori produzione
  RAL9010 White 70-184-05 Fuori produzione

Questo prodotto è stato ritirato.

The Extron RCM-SCLT is a double-space, Screen and Lighting Control Module AAP - Architectural Adapter Plate for use with the digital outputs of the MLC 104 IP Plus, or the relays of the MLC 206, MLC 226 IP, and System 5 IP. Once configured, it provides control to position a projection screen and adjust light settings.

Type: Quick Connect
Size: Double Space

Note: If you are using the MLC 104 IP Plus and your screen or lighting control system requires relay output, an IPA T RLY 4 will be required.

Caratteristiche

  • Double-space AAP - Architectural Adapter Plate
  • For use with the MLC 206, MLC 226 IP, and MLC 104 IP Plus MediaLink® Controllers and System 5 IP system switcher
  • Provides control to position a projection screen and adjust light settings
  • Available in black, white, or RAL9010 white

Nota: Part numbers 70-184-01, 70-184-02, 70-184-03 and 70-184-05 have been retired.

PRODOTTI SIMILI
  AC USB AAP Modulo di connettività AV AAP con presa AC e pigtail USB A
  CCR 2BLB Modulo di controllo remoto a chiusura di contatto con due pulsanti retroilluminati personalizzabili
  CCR 4BLB Modulo di controllo remoto a chiusura di contatto con quattro pulsanti retroilluminati personalizzabili
  Due adattatori USB A-USB B F-F
  Due connettori USB A F-F su pigtail da 25 cm
  Due connettori USB A-USB B F-F su pigtail
  Due interruttori a chiusura di contatto - Pulsante, polo singolo, doppio contatto con LED - Su linguette a saldare
  Gender changer per un connettore HD a 15 poli F-F
  Gender changer per un connettore HD a 15 poli F-F, un mini jack stereo da 3,5 mm su linguette a saldare
  Interface AAP Modulo di collegamento remoto a un'interfaccia

Specifiche

IRCM, ACM, RCM, and CM Series
General
   Power 
   CM-3BLB, CM-9BLB, CM-19AC 
       12 VDC from an Extron MLC 226 IP or MLC 104 IP Plus Series MediaLink Controller or System 5 IP Switcher
or from an optional external power suply
      Power input requirements  12 VDC, 0.02 A
   All other models 12 VDC from an Extron MediaLink Controller (MLC) or System 5 IP Switcher
      Power input requirements  12 VDC, 0.02 A
   Ambient temperature/humidity Storage: -40 to +158 °F (-40 to +70 °C) / 10% to 90%, noncondensing
Operating: +32 to +122 °F (0 to +50 °C) / 10% to 90%, noncondensing
   Rack mount Yes, with optional faceplate, and furniture/wall mountable with optional faceplates or AAP wall plates
   Enclosure type  Metal
   Enclosure dimensions 
      IRCM-VCR, IRCM-DVD, IRCM-Tape, ACM-Tone, ACM-Level, RCM-SC, RCM-SCLT, CM-5BB, CM-3BLB
         Faceplate 1.4" H x 3.5" W x 0.1" D (3.5 cm H x 8.9 cm W x 0.3 cm D) (double space AAP plate)
         Boards 1.3" H x 2.6" W x 0.9" D (3.3 cm H x 6.6 cm W x 2.3 cm D)
(Depth excludes buttons.  Allow at least 2.1" (5.3 cm) depth in the wall or furniture.)
      IRCM-DVD+, IRCM-DV+, CM-20BB, CM-9BLB, CM-19AC
         Faceplate 2.8" H x 3.5" W x 0.1" D (7.1cm H x 8.9 cm W x 0.3 cm D) (four space AAP plate)
         Boards 2.7" H x 2.6" W x 0.9" D (6.9 cm H x 6.6 cm W x 2.3 cm D)
(Depth excludes buttons.  Allow at least 2.1" (5.3 cm) depth in the wall/furniture.)
   Product weight  
      IRCM-VCR, IRCM-DVD, IRCM-Tape, ACM-Tone, ACM-Level, RCM-SC, RCM-SCLT, CM-5BB, CM-3BLB
       0.1 lbs (<0.1 kg)
      IRCM-DVD+, IRCM-DV+, CM-20BB, CM-9BLB, CM-19AC 
       0.2 lbs (0.1 kg)
   Shipping weight  1 lbs (1 kg)
   Vibration  ISTA 1A in carton (International Safe Transit Association)
   Listings UL, CUL as components of the MLC 206, or MLC 226 IP, or MLC 104 IP Plus Series MediaLink Controller; or System 5 IP Switcher
   Compliances CE, FCC Class A, VCCI, AS/NZS, ICES as components of the MLC 206, MLC226IP, or MLC 104 IP Plus Series MediaLink Controller; or System 5 IP Switcher
   Product warranty 3 years parts and labor
    NOTE     Specifications are subject to change without notice.
(7.52-053007-D4)

Pannello illustrativo

RCM-SCLT Panel Drawing